{"product_id":"1u1480376689-uk","title":"3D PRINTPRO HT, PC, 230V, 12V SS, FCS – UK (1U1480376689-UK)","description":"\u003cdiv class=\"et_pb_module et_pb_text et_pb_text_0_tb_body single-bofa-title  et_pb_text_align_left et_pb_bg_layout_light\"\u003e\n\u003cdiv class=\"et_pb_text_inner\"\u003e\n\u003ch1\u003e3D PrintPRO HT\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_text et_pb_text_1_tb_body single-bofa-subtitle  et_pb_text_align_left et_pb_bg_layout_light\"\u003e\n\u003cdiv class=\"et_pb_text_inner\"\u003e\u003cspan class=\"product-subtitle\"\u003eFor enclosed, high-performance 3D printers with up to 212°F (100°C) chamber air temperature\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_text et_pb_text_2_tb_body single-bofa-ideal-for  et_pb_text_align_left et_pb_bg_layout_light\"\u003e\n\u003cdiv class=\"et_pb_text_inner\"\u003e\u003cspan class=\"ideal-for-text\"\u003eIdeal For:\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eExtrusion printing.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"et_pb_text_inner\"\u003e\n\u003cdiv class=\"et_pb_module et_pb_text et_pb_text_3_tb_body single-bofa-content  et_pb_text_align_left et_pb_bg_layout_light\"\u003e\n\u003cdiv class=\"et_pb_text_inner\"\u003e\n\u003cp\u003eThe 3D PrintPRO HT provides a premium fume extraction solution for high-performing 3D printers operating with elevated chamber air temperatures. With a modular approach, the design caters to closed-loop continuous operation, open-loop intermittent operation, and the ability to do both with a pairing kit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAbility to filter gas up to 212°F\/100°C\u003c\/li\u003e\n\u003cli\u003eLow noise level\u003c\/li\u003e\n\u003cli\u003eLow heat loss through insulated construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApprovals: UKCA and CE\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_toggle et_pb_toggle_0_tb_body et_pb_toggle_item pb-toggle-open et_pb_toggle_open\"\u003e\n\u003ch2 class=\"et_pb_toggle_title\"\u003eFeatures\u003c\/h2\u003e\n\u003cdiv class=\"et_pb_toggle_content clearfix\"\u003e\n\u003cdiv class=\"bofa-key-features\"\u003e\n\u003cdiv class=\"bofa-key-feature\"\u003e\n\u003cdiv class=\"bofa-key-feature-image\"\u003e\u003cimg width=\"300\" height=\"300\" src=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/HEPA-icon-300x300.png\" class=\"attachment-medium size-medium wp-post-image\" alt=\"HEPA icon\" decoding=\"async\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature-content\"\u003e\n\u003ch3\u003eHEPA filter\u003c\/h3\u003e\n\u003cp\u003eOur HEPA filters are rated to filter 99.995% of particles at 0.3 microns.  A secondary filter to remove fine particulate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature\"\u003e\n\u003cdiv class=\"bofa-key-feature-image\"\u003e\u003cimg width=\"300\" height=\"300\" src=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/ACF-Technology-icon-300x300.png\" class=\"attachment-medium size-medium wp-post-image\" alt=\"ACF Technology icon\" decoding=\"async\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature-content\"\u003e\n\u003ch3\u003eAdvanced carbon filters\u003c\/h3\u003e\n\u003cp\u003eOur advanced carbon filters help to capture contaminants and odors, reducing the risk of bypass and tunneling. They are designed with specific carbon types tailored to industry applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature\"\u003e\n\u003cdiv class=\"bofa-key-feature-image\"\u003e\u003cimg width=\"300\" height=\"300\" src=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Multi-Voltage-Sensing-Unit-icon-300x300.png\" class=\"attachment-medium size-medium wp-post-image\" alt=\"Multi Voltage Sensing Unit icon\" decoding=\"async\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature-content\"\u003e\n\u003ch3\u003eMulti-voltage sensing\u003c\/h3\u003e\n\u003cp\u003eAutomatically senses the local voltage and adjusts accordingly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature\"\u003e\n\u003cdiv class=\"bofa-key-feature-image\"\u003e\u003cimg width=\"300\" height=\"300\" src=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Remote-stop-start-icon-300x300.png\" class=\"attachment-medium size-medium wp-post-image\" alt=\"Remote stop-start icon\" decoding=\"async\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature-content\"\u003e\n\u003ch3\u003eRemote stop\/start signal\u003c\/h3\u003e\n\u003cp\u003eOur remote stop\/start signal ensures that your Donaldson BOFA fume extraction system operates only when your machine is running, helping to save on both running costs and energy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature\"\u003e\n\u003cdiv class=\"bofa-key-feature-image\"\u003e\u003cimg width=\"300\" height=\"300\" src=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/09\/Filter-Change-Signal-300x300.png\" class=\"attachment-medium size-medium wp-post-image\" alt=\"\" decoding=\"async\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"bofa-key-feature-content\"\u003e\n\u003ch3\u003eFilter change signal\u003c\/h3\u003e\n\u003cp\u003eOur filter change signal alerts you when your filter is full and needs changing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_toggle et_pb_toggle_1_tb_body et_pb_toggle_item pb-toggle-open et_pb_toggle_open\"\u003e\n\u003ch2 class=\"et_pb_toggle_title\"\u003eTechnical specification\u003c\/h2\u003e\n\u003cdiv class=\"et_pb_toggle_content clearfix\"\u003e\n\u003cdiv class=\"bofa-technical-specification-content\"\u003e\n\u003ctable id=\"tablepress-40\" class=\"tablepress tablepress-id-40\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003c\/td\u003e\n\u003cth class=\"column-2\"\u003eImperial\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003eMetric\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-striping\"\u003e\n\u003ctr class=\"row-2\"\u003e\n\u003ctd class=\"column-1\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e23.94 x 15.98 x 23.23”\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e608 x 406 x 590 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3\"\u003e\n\u003ctd class=\"column-1\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e110 lbs\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4\"\u003e\n\u003ctd class=\"column-1\"\u003eAirflow \/ Pressure\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e22 cfm\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e80 m³\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5\"\u003e\n\u003ctd class=\"column-1\"\u003eElectrical data\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e115 V 60 Hz\u003cbr\u003eFull load current: 2 amps\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e230 V 50 Hz\u003cbr\u003eFull load current: 2 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6\"\u003e\n\u003ctd class=\"column-1\"\u003eNoise level (at typical operating speed)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;65 dBA\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u0026lt;65 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7\"\u003e\n\u003ctd class=\"column-1\"\u003eCabinet construction\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePowder-coated mild steel\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePowder-coated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_toggle et_pb_toggle_2_tb_body et_pb_toggle_item pb-toggle-open et_pb_toggle_open\"\u003e\n\u003ch2 class=\"et_pb_toggle_title\"\u003eDocumentation\u003c\/h2\u003e\n\u003cdiv class=\"et_pb_toggle_content clearfix\"\u003e\n\u003cdiv class=\"bofa-documentation-content\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Donaldson-BOFA-3D-PrintPRO-HT-Datasheet-UK-ENG-1.pdf\" rel=\"noopener\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Donaldson-BOFA-3D-PrintPRO-HT-User-Manual-UK.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Donaldson-BOFA-3D-PrintPRO-HT-Recirculation-User-Manual-UK.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser manual (Recirculation)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.donaldsonbofa.com\/wp-content\/uploads\/2024\/08\/Donaldson-BOFA-3D-PrintPRO-HT-Purge-User-Manual-UK.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser manual (Purge)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Filtration \u0026 Transmission Services (Pty) Ltd","offers":[{"title":"Default Title","offer_id":45674531619012,"sku":"1U1480376689-UK","price":126118.52,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/3395\/1428\/files\/3d-printpro-ht_54022893063_l.jpg?v=1767881898","url":"https:\/\/www.filtrationtransmission.co.za\/products\/1u1480376689-uk","provider":"Filtration \u0026 Transmission Services (Pty) Ltd","version":"1.0","type":"link"}